Information Bulletins
 
 
   
Email update series
 
|
Muriatic Acid and the Acid Column
Myth
  
  
The lowering of Total Alkalinity (TA) and/or pH in swimming pools utilizing
muriatic acid has been an accepted procedure in the pool industry for many
decades. The reactions involved have been documented and published in widely
available texts. However, a myth has seeped into the literature and into
chemistry seminars provided to service personnel. This particular myth is
that different methods of acid application have the effect of producing
different amounts of alkalinity and pH reduction in the pool. Examples of
the myth can be found in a Pool & Spa News article, a Service Industry
News publication, a water chemistry handbook, and the NSPF coursebook *
and can be summarized:
An examination of the claims show that they do not make sense:
Acid Column Claim: While pouring acid in a localized area, the
pH is lowered dramatically in a localized column of the pool water. Yet
the claim is that once this low pH column of water mixes in, this acid
addition will somehow not significantly lower the pH of the entire pool!
Also, somehow the alkalinity of the entire pool will be significantly (or
extraordinarily) reduced reduced by an amount above and beyond what
that given amount of acid would normally provide when added by a different
method! We are to understand that this skewed effect is somehow
by means of chemical shortcuts associated with a CO2 gasoff
from the affected column and a hypothetical direct conversion of carbonate
to carbonic.
Acid Dilution Claim: When trickling in diluted acid around the
pool, the pH of a localized area of water is not lowered significantly;
rather, a gradual reduction of the pH is achieved throughout the pool.
Yet the claim is that, after mixing, this method will lower the pH of the
entire pool water more dramatically, or more effectively than when a column
is used! In addition, it is claimed that very little alkalinity reduction
will result from this method of application (or if it does, only after
a period of time...). Somehow we are to understand that the diluted, dispersed
acid does not affect the alkalinity level of the pool the same way acid
in a concentrated, localized form would.
Relevant Facts: The following points are key issues which, if
understood, invalidate the acid column myth:
- At normal pool pH levels, there is little or no carbonate alkalinity.
The alkalinity is bicarbonate (HCO3).
- When you add muriatic acid to water, bicarbonate alkalinity is converted
to carbonic acid (HCO3 + H+ = H2CO3), and is not alkalinity anymore.
- Although other factors complicate exact calculations for pH reduction,
alkalinity is straightforward: A given amount of acid added to a given
volume of water will always effect the same alkalinity reduction.
- Carbonic acid is water and dissolved CO2 (H2CO3 = CO2 + H2O).
- Although dissolved CO2 may slowly offgas (depending on what else you
do to the water...), this process takes a long time days or more.
Also, there is a balance: CO2 can also dissolve from the air back into
the water.
- It takes 1600ppm of CO2 to make bubbles of CO2 in water. In a pool
with 250 total alkalinity, if all of the alkalinity were converted to CO2
it would only make 220ppm CO2. There is never enough bicarbonate in the
water to cause the formation of CO2 bubbles.
- Although there are some factors, such as pressure or temperature, which
make CO2 offgas faster (try heating up your can of soda pop, or leaving
it open for a few minutes...) pH is not one of them.
Testing in pools Careful experiments were conducted in both vinyllined
and inground plaster pools to verify results under controlled, documented
conditions. A pH meter with 3 submersible probes and datalogging equipment
was used to verify low pHs as demanded by the acid column method.
Initially the alkalinity and pH was increased with sodium bicarbonate, soda
ash, and sodium hydroxide to create conditions where the addition of 2 quarts
of acid would be a normal procedure. (These same chemicals were used subsequently
between tests to reestablish test conditions.) The water was allowed to
stabilize, and then the acid was added via the different methods. Tests
were also conducted to determine the pH at the bottom of a noncirculating
pool after concentrated acid has been added in a localized area. The water
was also labtested for pH, total alkalinity, total hardness, calcium
hardness, total dissolved solids, iron, copper, chlorine, and cyanuric acid.
In the first application method (acid column method) the muriatic acid (with
pHsensitive dye added) was poured into the pool undiluted at a single
surface location in a short amount of time with the filtration/circulation
system turned on. Acid was poured in the deep end of the pool so that probe
#2 would verify the pH of the acid column. The dye verified
the flow and pH of the acid. Full pH and alkalinity reduction occurred using
this method in all repetitions of the test. Although a definite acid
column (pH lower than 4.0 in a localized, defined area) was created,
at no time were there visual bubbles or effervescence.
In the next application method (dilute & distribute method) the dyed
acid was poured into a five gallon bucket containing 3 gallons of pool water.
This solution was then gently agitated for mixing, and then, with the system
running, the acid was dribbled into the pool approximately 18" from
the edge, while walking a complete circuit of the perimeter of the pool.
Full pH and alkalinity reduction occurred using this method in all repetitions
of the test.
Since the second method represented a best case scenario of
how acid may be added to a pool, a final application method (acid puddle
method) was used for contrast. The location of the probes remained the same.
This time the dyed acid was introduced undiluted and in a single location
at the deep end of the pool. The circulation system was left off for twenty
minutes, and then turned on for the rest of the test period (three days).
Full pH and alkalinity reduction occurred using this method in all repetitions
of the test. Although a definite acid puddle (pH lower than
2.5 in the bowl of the pool) was created, at no time were there visual bubbles
or effervescence rising from the puddle.
(NOTE) There are times when pool plaster is intentionally subjected
to low pH levels for example in the case of acid washing the plaster,
either with the pool filled or drained. We dont contend that these
processes are detrimental or invalid. The etching or acidwashing of
the plaster surface to remove minerals or materials deposited on the surface
is done intentionally by professionals using controlled procedures, with
care taken to uniformly affect the pool surface. Even spot applications
are done intentionally with professional, controlled techniques. We do contend
that acid application to etch/clean should be undertaken only when that
is the intent and when it is beneficial to do so, but not undertaken inadvertently
when the actual intent is only to affect the water balance. Acid column
creation subjects random localized areas of the plaster (typically in the
deep bowl of the pool) and also the circulation system to etching chemical
conditions.
An informal poll of servicemen, builders, and homeowners indicated that
not all service technicians will turn the pool system on to help dilute
the acid that is added. Some service technicians incorrectly believe that
having the pool equipment off will help achieve the lower pH desired in
a localized area for maximum reduction of alkalinity. This practice seems
particularly dangerous with the advent of newer pools, since many are smaller
and shallower, creating a greater potential for damage.
It is unfortunate for professionals (the experts) to promote
the acid column concept for reducing alkalinity. At what cost is the industry
adopting new programs and what amount of risk is the industry willing to
take in order to save what, even if the theory had any validity, must be
only a few pennies in time and acid?
(Where to go for more detail) An indepth report of this
project is available, which includes a) all of the chemical and mathematical
calculations, b) a complete rationale for each point, c) and a complete
description of each test pool and method, so that the experiments may be
redone by anyone with a good pH meter and alkalinity titration setup. To
obtain a copy of the complete report, request Volume 1 Number 2 of the Journal
of the Swimming Pool and Spa Industry (5205736696).
* Footnotes:
- Pool & Spa News, quoting Cal Eden, March 12, 1990, p. 70
- Dickman, David and Lowry, Robert, Guide to pH, Alkalinity, Water
Testing, and Water Balance, (Service Industry News, 1988), p. 10
- P. Kirk Mitchell, The Proper Management of Pool and Spa Water,
(Hydrotech Chemical, 1988) pp. 33, 34
- PoolSpa Operators Handbook, ed. by L. Kowalsky (National Swimming
Pool Foundation, 1990) pp. 39, 40
(Additional information regarding this subject appeared in the January
26th, 1994 issue of Pool & Spa News.)
Graph A - Acid Column (Roll-in
This is a profile of the pH changes when undiluted acid was rolled
in using the acid column technique, with the filter system on. Probes
were located in the hair/lint strainer, on the main drain, and 18"
above the main drain. With a starting pH of 8.3 the overall pH drop from
the addition of 2 quarts acid in a 11 - 14 thousand gallon pool was approximately
.6 pH units. The requirements of the technique call for a localized area
of pH lower than 5 (or 4.4). This requirement was met in all three probe
locations for periods of 1 to 4 minutes. The acid dropped past the middle
probe fairly quickly (1 minute or less), puddled briefly (ca. 3 minutes),
and slightly diluted into the pump area for about 4 minutes. The pH in all
areas of the pool rebounded to safe levels approximately 10 minutes after
the acid application. The pH in all three areas rebounded to approximately
7.7 after 45 minutes. The water was in a condition commonly accepted as
extremely detrimental to the plaster in the main drain area for over 4 minutes,
and in an extremely detrimental condition in the pump area for over 6 minutes.
Graph B - Dilute and distribute
This is a profile of the pH changes when the acid was diluted and
distributed around the pools with the filter system on. Probes were located
in the hair/lint strainer, on the main drain, and 18" above the main
drain. With a starting pH of 8.3 the overall pH drop from the addition of
2 quarts acid in a 11 - 14 thousand gallon pool was approximately .6 pH
units. When the acid is sufficiently diluted and walked around
the perimeter of the pool, the lowest the pH ever dropped was to approximately
7.2 in the pump. Main drain and middle pH only went down to around 7.4.
The pH in all three areas rebounded to approximately 7.7 after 45 minutes.
At no time was the pH at a level commonly considered to be detrimental to
the plaster or equipment.
Graph C - Acid puddle
This is a profile of the pH changes when the acid was puddled
on the bottom by adding undiluted acid with the filter system off. Probes
were located in the hair/lint strainer, on the main drain, and 18"
above the main drain. With a starting pH of 8.3 the overall pH drop from
the addition of 2 quarts acid in a 11 - 14 thousand gallon pool was approximately
.6 pH units. The pH in all three areas rebounded to approximately 7.7 after
45 minutes. Since the water was static for the first 20 minutes of the test,
the acid slipped under the middle probe and only affected it slightly. The
pH at the main drain plummeted immediately to 2.1 and remained there until
the system was turned on, at which time the acid puddle was drawn into the
pump. As soon as the puddle had passed into the piping system, the pH at
the drain and then the pump climbed rapidly with the contact from water
drawn from unaffected areas of the pool. The breakdown of the concentrated
puddle was minimal until the puddle was drawn into the circulation system.
The pH 18" off the pool floor was never low enough to cause harm, but
the pH at the bowl of the pool was low enough to be what is generally considered
extremely detrimental to plaster for an extended period of time, and presumably
would have remained so until water movement from an outside source (pump
or brushing) could force the puddled acid apart. The pH in the pump was
at a level considered to be extremely detrimental for a 3 to 4 minute period
as the slug of acidified water passed through it.
|
 
 
 
 
 
|